Search results for "solar [WIMP]"
showing 10 items of 229 documents
Numerical procedures and their practical application in PV modules’ analyses. Part II: Useful fractions and APE
2019
Abstract The article regards aspects of PV modules tested with the use of natural sunlight. The analysis of spectral structure of solar energy resources in southern Poland, carried out on the basis of meteorological data originating from SolarLab PW Wroclaw and AGH Krakow, Poland [ 1 ] was used in the article. It is a continuation of the article: Analysis of solar energy resources in southern Poland for photovoltaic applications [ 1 ], describing the method to determine spectral parameters of average photon energy (APE) and useful fraction (UF) with the use of a solar radiation spectrum simulator. This article, however, includes an experimental presentation of their impact on PV conversion …
Reconfiguration strategies to reduce mismatch effects on PV array: An Arduino-based prototype
2014
Today, solar energy represents a widespread source of electricity among all the renewable energies. One of the major problems concerning the photovoltaic (PV) arrays is the partial shading, that is the non-uniform irradiance on its parts. The partial shading leads to several undesired effects, such as mismatch between modules and a reduction of the production of electric energy. In order to alleviate the partial shading effects, different methods can be employed. Among them, the reconfiguration of the electrical connections between modules represents an alternative solution. In this paper, an algorithm of reconfiguration for a small-scale PV plant is proposed and experimental results showin…
Maintance by water-cleaning and efficiency reduction of pv panels
2019
With the increase in the use of solar energy, both in civil and industrial environments, the problem of maintenance of photovoltaic panels becomes extremely important. In this work attention is restricted to the problem of cleaning and safety conditions of the photo-voltaic (PV) panels and a brief review of main effects determining their efficiency reduction are reported. The discussion related to problems and unsafe functioning conditions concludes this paper.
Proof of Concept of an Irradiance Estimation System for Reconfigurable Photovoltaic Arrays
2015
In order to reduce the mismatch effect caused by non-uniform shadows in PV arrays, reconfigurable interconnections approaches have been recently proposed in the literature. These systems usually require the knowledge of the solar radiation affecting every solar module. The aim of this work is to evaluate the effectiveness of three irradiance estimation approaches in order to define which can be well suited for reconfigurable PV arrays. It is presented a real-time solar irradiance estimation device (IrradEst), implementing the three different estimation methods. The proposed system is based on mathematical models of PV modules enabling to estimate irradiation values by sensing a combination …
Integration of distributed on site control actions via combined photovoltaic and solar panels system
2009
A systematic evaluation of the potential energy saving and CO2 emissions reduction on buildings was carried out, when a renewable energy system is locally installed. The exploitation of a combined solar and photovoltaic system and the integration of suitable energy management actions were deeply investigated. A model of these solar and photovoltaic components has been developed and included within a complete house simulator, capable to precisely figure out the daily electric energy consumptions of typical apartments and to measure the positive actions induced by the added renewable energy. Saving up to 40% on the energy consumptions and even more savings on wiring losses seems to be easily …
Multicriteria evaluation of sustainable energy solutions for Colosseum
2017
Abstract Colosseum is a large office building in the capital region of Finland. The building owner operates on the highly competitive office rental market. With increasing emphasis on environmental responsibility, energy efficiency and sustainable energy solutions can provide competitive edge on the rental market. This study evaluates in terms of multiple criteria different alternatives to enhance the energy solutions of the building. The alternatives included different configurations of solar power, ground source heat, and roof constructions, along with district heating. Decision criteria included internal rate of return, energy efficiency, CO2 emissions, and attractiveness. Attractiveness…
MED parallel system powered by concentrating solar power (CSP): model and case study: Trapani, Sicily
2014
Abstract: This work presents an overlook on a new model that simulates the physical operation in steady state of a multi-effect distillation (MED) plant with parallel-feed (P) configuration. This model includes the consumption of steam with steam ejectors, and its validation was done using data from a real MED industrial plant using a thermal vapor compressor (TVC) operating in Italy, in the Sicilian city of Trapani. Results show that the MED model returns accurate predictions of the plant behavior, very useful for a first analysis on such type of investments. This MED model was also integrated into the system advisor model developed by the US National Renewable Energy Laboratory. Simulatio…
A simple and accurate model of photovoltaic modules for power system design
2014
Conceptual study of the coupling of a biorefinery process for hydrothermal liquefaction of microalgae with a concentrating solar power plant
2017
A conceptual analysis of the coupling of a concentrating solar power plant with a chemical process for hydrothermal liquefaction (HTL) of microalgae to biocrude was performed. The two plants were considered coupled by molten salt recirculation that granted energetic supply to the chemical process. Preliminary estimations have been done considering a solar field constituted by 3 linear parabolic solar collectors rows, each 200 m long, using a ternary molten salts mixture as heat transfer fluid, and a chemical plant sized to process 10 kT/y of microalgae. Under adopted conditions, we have estimated a minimum selling prize of the biocrude that is similar to that achieved in non-solar HTL proce…
Reconfiguration Techniques of Partial Shaded PV Systems for the Maximization of Electrical Energy Production
2007
In this paper, the research of the optimal layout of photovoltaic (PV) modules in a PV array giving the maximum output power under different shaded working conditions is carried out. The particular condition of non uniform solar exposition of the modules is analyzed. The study of the different configurations has been carried out starting from a circuital model used for the design of PV cells and for the simulation of the working behavior of PV arrays. The attained results appear to be interesting although the complexity of the problem in mathematical terms is huge when the number of panels is high. Moreover, the results confirm that this approach often allows to attain a higher electrical e…